Add to Cart
Custom Drive in Climatic Test Chamber Temperature Humidity Environmental Test Chamber
Walk-in Rooms Related Knowladge
Tempreture table for reference
cold storage goods | tempreture range |
processing room | 10C |
fruit, vegetable, dry food | 0C~-5C |
medicine, cake, pastry, chemical material | 0C~-5C |
ice storage room | -5~-10C |
fish, meat storage | -18~-25C |
deep freezer. | -25C~-35C |
Compressor type and condenser
compressor type | (Germany) | refcomp(italy) | copeland(US) | manurope(France) |
condenser | air cooled | water cooled | evapoarating |
Panels information
office Foam panel | 50mm thickness |
processing room 10C | 50mm/ 75mm PU |
5C | 75mm/ 100mm PU |
-18C | 100mm/ 150mm PU |
-25C/ -35C | 150mm/200mm PU |
panel steel cover | SS, GI, aluminum etc |
Specification of Standard Walk-in Oven
SPECIFICATIONS | Note: We reserve the right to change specifications without prior notice | ||||||
Model | KMHW- | ||||||
4 | 6 | 8 | 13 | 17 | 21 | ||
Volume(m³) | 9 | 12.9 | 16.8 | 16.8 | 35.2 | 13.3 | |
Interior Dimensions | W(mm) | 2100 | 3000 | 3900 | 3000 | 3900 | 4800 |
H(mm) | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | |
D(mm) | 2050 | 2050 | 2050 | 4300 | 4300 | 4300 | |
Exterior Dimensions | W(mm) | 3250 | 4160 | 5050 | 5050 | 5050 | 5950 |
H(mm) | 2350 | 2350 | 2350 | 2350 | 2350 | 2350 | |
D(mm) | 2250 | 2250 | 2250 | 2250 | 4500 | 4500 | |
Control System | Balanced Temperature & Humidity Control System | ||||||
Temp. range | Maximum:80ºC,120ºC;Minimum:-60ºC,-50ºC,-40ºC,-30ºC,-20ºC,-10ºC,0ºC | ||||||
Humidity Range | 10%,20%,30%~95% | ||||||
Temp. constancy | ±0.5ºC | ||||||
Humidity constancy | ±2.5%R.H | ||||||
Temp. uniformity | ±2.0ºC | ||||||
Humidity uniformity | ±5.0%R.H | ||||||
Heat up time | +20ºC~+80ºC ,Within 60 min | ||||||
Pull down time | +20ºC~-55ºC -40ºC-20ºC-10ºC ,Within 120 or 90 or 60 min | ||||||
Interior material | Stainless Steel Plate(SUS 304) | ||||||
Exterior material | Baked Painting Steel Or Stainless steel(SUS304) | ||||||
Insulation material | Rigid polyurethane foam | ||||||
Door size (mm) | Single wing:W800*H1800;Double wing:W1600*H1800; | ||||||
Safety Devices(standard) | No fuse breaker, over pressureover heat and over current protection for compressor, over temperature protection, over load protection for blower, dry heat protection | ||||||
Standard accessories | Sight window*1,cable port(portΦ50mm)*1,chamber lamp*1, status indicator | ||||||
Refrigeration system | Water Cooled | ||||||
Semi-hermetic compressor, single stage or cascade refrigeration system | |||||||
CFC free refrigerant(HFC-507 and HFC-23) | |||||||
Controller | Panel | 7-inch LCD Touch panel,Chinese or English display selectable | |||||
Operation model | Program or fix point running | ||||||
Memory capacity | 120 programs,1200steps, all repeat 999 cycles,part repeat 99 cycles | ||||||
Accuracy | Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit | ||||||
Input | Temp.:pt-100, Humidity:pt-100 or ~5V DCV | ||||||
Comm.port | RS-232 or RS-485 (Softawre is option) | ||||||
Ambient Temp. | +5ºC~+35ºC | ||||||
Wiring method | AC 380±10%50Hz ,3 phase 4 wires +Ground Wires | ||||||
Note: 1. We reserve the right to change specifications without prior notice | |||||||
2.Customized sizes and configurations available |
Overview
An environmental test chamber artificially replicates the conditions under which machinery, materials, devices or components might be exposed. It is also used to accelerate the effects of exposure to the environment, sometimes at conditions not actually expected. These conditions may include:
1) Extreme temperatures
2) Sudden and extreme temperature variations
3) Moisture or relative humidity
4) Electrodynamics vibrations
5) Electromagnetic radiation
6) Salt spray
7) Rain
8) Weathering
9) Exposure to sun, causing UV degradation
10) Vacuum
Manufactured samples, specimens, or components are placed inside the chamber and subjected to one or more of these environmental parameters to determine reliability or measure after-effects such as corrosion. In the case of machinery such as internal combustion engines, byproducts such as emissions are monitored.
An environmental chamber can be a small room used both to condition test specimens and to conduct the test. It can be a smaller unit that's used for conditioning test items. Also, some chambers are small enough to be placed onto a universal testing machine or other test apparatus.
Many chambers are set at a certain set of conditions. Others can be programmed to cycle through specified sequences of conditions.
Design
As test requirements may be relatively simple or complex, environmental test chambers vary widely in size, ranging from small units designed for placement on bench tops to large walk-in chambers. Test chambers generally have viewports or video feeds to allow for visual inspection of the sample during the test. Reach-in chambers provide an opening that technicians may use to handle test samples. Chambers providing interior visual lighting must take into account the heat generated and compensate accordingly.
As with the wide variance in size, a number of user control options are available, ranging from simple analog indicators up to more modern digital readouts with LCD displays. Chambers may be computer programmable, and networked or Web-enabled test chambers are also available.[1]
Types of test chambers
1) Mechanically cooled test chambers
2) Liquid nitrogen cooled test chambers
3) Modular Walk-in Chambers