
Add to Cart
10CBM,17CBM, 24CBM Environmental Temperature Humidity Walk-In Chamber / Walk In Room
For electronics, home appliances, office machines and other requirements of the industry reliability test conditions, customized to meet the printer, washing machines, refrigerators and other needs of different types of environmental chambers.
1. GB11158 Technical conditions for high-temperature testing room
2. GB10589-89 Technical conditions for low-temperature testing room
3. GB/T10586-89 technical conditions for humidity testing room
4. GB/T2423.1-2001 testing methods for low-temperature
5. GB/T2423.2-2001 testing methods for high-temperature
6. GB/T2423.3-93 technical conditions for humidity testing room
7. GB/T2423.4-93 testing method for alternating hot and humid
8. IEC60068-2-1.1990 testing methods for low-temperature
9. IEC60068-2-2.1974 testing methods for high-temperature
10. GJB150.3 High-temperature test
11. GJB150.4 Low-temperature test
12. GJB150.9 muggy test
13. GB/T2423.22 temperature test
Model | KMHW-24(walk-in room) | |||||||
Volume(m³) | 24CBM | |||||||
Interior Dimensions | W5200 x H2500 x D2200mm | |||||||
Exterior Dimensions | W540 x H2750 x D2400mm | |||||||
Safety Devices(standard) | No fuse breaker, over pressure, over heat and over current protection for compressor, over temperature protection, over load protection for blower, dry heat protection | |||||||
Standard accessories | Observation window*1, cable port ( portΦ50mm ) *1, chamber lamp*1, status indicator | |||||||
Control System | Balanced Temperature & Humidity Control System | |||||||
Refrigeration system | Water Cooled | |||||||
Semi-hermetic compressor, single stage or cascade refrigeration system, | ||||||||
CFC free refrigerant ( HFC-507 and HFC-23 ) | ||||||||
Controller | Panel | 7-inch LCD Touch panel, Chinese or English display selectable | ||||||
Operation model | Program or fix point running | |||||||
Memory capacity | 120 programs,1200steps, all repeat 999 cycles,part repeat 99 cycles | |||||||
Accuracy | Temp.:0.1% of F.S ± 1 digit Humidity:0.1% of F.S ± 1 digit | |||||||
Input | Temp.: pt-100, Humidity: pt-100 or ~5V DCV | |||||||
Comm.port | RS-232 or RS-485 ( Softawre is option) | |||||||
Temp. range | Maximum: 80 ºC,120 ºC; | |||||||
Humidity Range | 10%, 20%, 30% ~ 95% | |||||||
Temp. constancy | ±0.5 ºC | |||||||
Humidity constancy | ±2.5%R.H | |||||||
Temp. uniformity | ±2.0 ºC | |||||||
Humidity uniformity | ±3.0%R.H or 5.0%R.H | |||||||
Ambient Temp. | +5 ºC~+35 ºC | |||||||
Wiring method | AC 380 ± 10% 50Hz ,3 phase 4 wires + Ground Wires | |||||||
Heat up time | +20 ºC~+80 ºC, Within 60 min | |||||||
Pull down time | +20 ºC ~ -55 º, -40 ºC, -20 ºC, -10 ºC, Within 120 or 90 or 60 min | |||||||
Interior material | Stainless Steel Plate(SUS 304) | |||||||
Exterior material | Baked Painting Steel Or Stainless steel ( SUS304) | |||||||
Insulation material | Rigid polyurethane foam | |||||||
Door size (mm) | Single wing: W800 x H1800; Double wing: W1600 x H1800; | |||||||
Note:1. We reserve the right to change specifications without prior notice 2.Customized sizes and configurations available |
a. Touch panel for the convenient input of fixed values and programming with graphic depiction of nominal and real values, operating time, remaining cycles etc., including help functions
b. Programme memory for up to 100 programmes with a total of 1000 sections
c. Software support for potential-free inputs and outputs
d. Password protection, two-stage, to avoid unintentional alteration
e. Integrated limit value monitoring system for temperature and humidity
f. Inspection system provides information on malfunctions and collects operating time dat
climatic test chambers
thermal shock test chambers
walk-in chambers
Drive-in chamber
burn-in rooms
aging test chambers
vibration chamber
temperature humidity and vibration three integrated test chamber
drying ovens
salt spray testers and medical laboratory equipment