Add to Cart
LCD touch screen controller stainless steel plate 1000L rapid Temperature Change Chamber
Control method and characteristics
High precision microcomputer temperature and humidity systems by PID controlling SSPR reduce the
system’s heating and humidification amount, to achieve low power consumption, energy saving, carbon
reduction effect. Intelligent electronic control of cooling, heating, humidity control, so it could be used
long-term stability.
Application
It is suitable for the cold resistance test of the electricians, electronic products and parts, and the
adaptability test under the conditions of rapid temperature change or gradual change. It is especially
suitable for the environmental stress screening test of electronic and electrical products.
Prouduct Specifications
Temperature | |
Temperature range | -75℃ ~ +150℃ |
Temperature deviation | ≦±2.0℃ |
Temperature fluctuat ion | ±0.5℃ |
Temperature unifor mity | ≦2.0℃ |
Temperature change rate | Temperature change rate designed according to IEC 60068-3-5 standard, Sensors in the outlet Heating rate: from -75℃ to +150℃ linear 15℃/min no load Cooling rate: from +150℃ to 75℃ linear 15℃/min no load |
Humidity | |
Humidity range | 10%R.H.~98%R.H |
Humidity deviation | ±3.0%RH(>75%RH)±5.0%RH(≤75%RH) |
Humidity uniformity | 3.0%RH (no load) |
Humidity fluctuation | ±2.0%RH |
Chamber Structure | |
Overall structure and chamber was composed of three parts as below. Insulation box, separate refrigeration units, and electrical control cabinet. | |
Chamber size | Workspace volume: W 1000 × H 1000 × D 1000 mm Exterior size: W 1200 × H 2030 × D 3095 mm (about) |
Insulation box | wall material: high-quality carbon steel with static color spray inner wall material: SUS304 # matte stainless steel plate Insulation materials: rigid polyurethane foam insulation layer + glass fiber. |
Door | Single door. Heating wire was installed at the door frames to prevent condensation at low temperatures. |
Observation window | Observation window on the door. Multi-layer hollow electro-thermal coating glass can effectively heat insulation and prevent condensation. |
Lighting device | 11W/AC220V lamp on the observation window |
Heater | High-quality nickel-chromium alloy wire electric heater, non-contact control |
Humidification | Humidifying basin heating and humidifying method; Stainless steel sheathed heater; Heater control: non-contact pulse width modulation, SSR (solid-state relay); Water level control device, heater anti-dry device. |
Condensate water outlet | Equipped with condensing water and condensate drainage unit |
Cable port | Φ50mm*1 located on both sides(each*1) with rubber stopper and plastic cover |
Sample holder | Two layers of stainless steel sample holder, load capacity 30kg/layer |
Mobile casters | Containing mobile casters (with goblet) |
Electric control box | Total power circuit breaker, over-temperature protection. ply |
Water Pump System | Water pump of automatic water sup |
Features
● GB-2423.1-2008(IEC68-2-1) test A: low-temperature test
● GB-2423.2-2008(IEC68-2-2) test B: high-temperature test
● GJB360.8-2009(MIL-STD.202F) Life of high temperature test
● GJBl50.3-2009(MIL-STD-810D) high-temperature test
● GJBl50.4-2009(MIL-STD-810D) low-temperature test
● GB2423.3-2008(IEC68-2-3) test Ca: constant damp heat test
● GB2423.4-2008(IEC68-2—30) test Db: Alternating hot and humid test method.
● GJBl50.9-2009(MIL-STD-810D) Damp heat test method.