Add to Cart
High Efficiently 3-zone Climatic Thermal Shock Environmental Chamber
Product Description
As we know that thermal shock occurs when a thermal gradient causes different parts of an object to expand by different amounts. This differential expansion can be understood in terms of stress or of strain, equivalently. At some point, this stress can exceed the strength of the material, causing a crack to form. If nothing stops this crack from propagating through the material, it will cause the object's structure to
fail. Normally we use thermal shock test equipment to test how much amount can a product withstand thermal shock.
Thermal shock testing exposes products to alternating low and high temperatures to accelerate failures caused by temperature cycles or thermal shocks during normal use. The transition between temperature extremes occurs very rapidly, greater than 15 °C/min.
Applications
3-zone Thermal shock chamber have been designed to operate in accordance with reliability programs, quality control, commercial test programs and medical tests. It is used to test the capability of material structure or composite material to withstand the continuous environmental changes between extremely high temperature and low temperature during a short period. It is applicable to metals, plastic, rubber, electronics amongst other materials. The test result can be used as a reference or basis for produce improvement.
Features
1.Thermal shork chamber in each zone for peak demand of heating and cooling. Provides extra thermal energy to efficiently meet the MIL-STD 883 requirements.
2.Temperature recorder provides 24 hour part temperature recording as the load travels from zone to zone. Using touch-control graph control as operation interface, easy to operate.
3.The system can be used for automatic Circulation Shock or manual selective shock, capable of setting two zones or three zones shocks as well as cold and thermal shock start-up.
4.Custom-made and optional accessories available.
Standards Implement and Met
GB/T 2443.1-2001 Test A: Low temp. Test;
GB/T 2443.2-2001 Test B: Low temp. Test;
GB/T 2443.22-2002 Test N: Low temp. Test;
GJB 150.3-1986 High Temp. Test;
GJB 150.4-1986 Low temp. Test;
GJB 150.5-1986 Temp. Impact Test;
(Load refer to 5.5.5 no active load)
Working Principle
This is so called three-zone type thermal shock test chamber.
Sample is placed in the test chamber, more extreme temperature than test temperature can be set in high-temperature chamber and low-temperature chamber. When it comes to low temperature test, cold chamber door open, and low-temperature chamber working together with test chamber.
When converted into high-temperature test, cold chamber door closed, hot chamber door are opened, and test chamber working together with high-temperature chamber.
Conversion of mechanical action (transferring from high temperature to low temperature or low temperature to high temperature) can be completed in less than 1second, and the temperature can be quickly stabilized.
During the whole test, test sample is no need to be moved, and without any human intervention.
Specifications
(1) KTS-A Series
Model |
| ||||||||
72A | 100A | 150A | 200A | 252A | 300A | 480A | |||
Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | |
H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | ||
D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | ||
Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | |
H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | ||
D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | ||
Test weight | 5 | 10 | 12 | 15 | 18 | 20 | 20 | ||
Low Temp Chamber | -55ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-55ºC | ||||||||
Test Chamber | -40ºC~+150ºC | ||||||||
High Temp Chamber | +60ºC~+200ºC ,Within 20 min, Pre-heating time | ||||||||
Transition time | ≤15S | ||||||||
Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | ||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | |||||||||
≤ 5 min | |||||||||
Ambient Temp. | +5ºC~+35ºC | ||||||||
Power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
(2) KTS-B Series
Model |
| ||||||||
72B | 100B | 150B | 200B | 252B | 300B | 480B | |||
Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | |
H | 400 | 450 | 500 | 600 | 600 | 600 | 800 |
D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | |
Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 |
H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | |
D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | |
Test weight(KG) | 5 | 10 | 12 | 15 | 18 | 20 | 20 | |
Low Temp. chamber | -70ºC~-10ºC ,Pre cooling time: +20ºC~-70ºC ,≤ 60 min | |||||||
Test. Chamber | -55ºC~+150ºC | |||||||
High Temp. chamber temperature | +60ºC~+200ºC,Preheating time: ≤20 min | |||||||
Transition time | ≤15S | |||||||
Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | |||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | ||||||||
≤ 5 min | ||||||||
Ambient Temp. | +5ºC~+35ºC | |||||||
Power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
(3) KTS-D Series
Model |
| ||||||||
72D | 100D | 150D | 200D | 252D | 300D | 480D | |||
Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | |
H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | ||
D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | ||
Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | |
H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | ||
D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | ||
Test weight | 5 | 10 | 12 | 15 | 18 | 20 | 20 | ||
Low Temp Chamber | -80ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-80ºC |
Test Chamber | -65ºC~+150ºC |
High Temp Chamber | +60ºC~+200ºC ,Within 20 min, Pre-heating time |
Transition time | ≤15S |
Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample |
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | |
≤ 5 min | |
Ambient Temp. | +5ºC~+35ºC |
Power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |